Solution Delivery/Integrating Video Intercom with Acccess Control
Contents
[hide | ◄ ► ]Description
This article will show how to wire the Normally Opened relay on the Video Intercom to the PUSH connection on our Access Control. This will act as a Request to Exit button when the door on the Video intercom is triggered.
The Video Intercom relays can be triggered from a VTH or through DMSS. In this tutorial we'll be using a siren/light to act as a door activating on Normally Open relay 1. We will be wiring the Normally Open Relay from the Video Intercom to "PUSH1" to act as a REX for NO1/NC1 on the access Controller
Prerequisites
- Access Controller
- Dahua Video Intercom Setup
Step by Step Instructions
Physical Wiring
1. Wire the Door_NO relay to the PUSH1 of the Access control and Wire the Door_COM from the Video Intercom to COM1 Access Controller
2. Insert the connector to the Access Control
3. Then Wire your door to your controller. Our "Door" is a Normally Opened device so we will wire the Door to NO1 and COM1
How to open door via VTH
1.
2.