Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"

(Contact 3)
(Contact 3)
Line 128: Line 128:
 
|-
 
|-
 
|Black and red
 
|Black and red
|
+
|[[File:Wire_black_red_stripe.svg|35px]]
 
|RX
 
|RX
 
|RS-232 receiving port.
 
|RS-232 receiving port.
 
|-
 
|-
 
|Black and orange
 
|Black and orange
|
+
|[[File:Wire_black_orange_stripe.svg|35px]]
 
|TX
 
|TX
 
|RS-232 sending port.
 
|RS-232 sending port.
 
|-
 
|-
 
|Black and blue
 
|Black and blue
|
+
|[[File:Wire_black_blue_stripe.svg|35px]]
 
|GND
 
|GND
 
|Connected to the common GND port.
 
|Connected to the common GND port.
 
|-
 
|-
 
|Black and gray
 
|Black and gray
|
+
|[[File:Wire_black_gray_stripe.svg|35px]]
 
|SR1
 
|SR1
 
|Used for door contact detection.
 
|Used for door contact detection.
 
|-
 
|-
 
|Black and green
 
|Black and green
|
+
|[[File:Wire_black_green_stripe.svg|35px]]
 
|PUSH1
 
|PUSH1
 
|Door open button of door No.1
 
|Door open button of door No.1
 
|-
 
|-
 
|Black and brown
 
|Black and brown
|
+
|[[File:Wire_black_brown_stripe.svg|35px]]
 
|DOOR1_COM
 
|DOOR1_COM
 
|Lock control common port.
 
|Lock control common port.
 
|-
 
|-
 
|Black and yellow
 
|Black and yellow
|
+
|[[File:Wire_black_yellow_stripe.svg|35px]]
 
|DOOR1_NO
 
|DOOR1_NO
 
|Lock control normally open port.
 
|Lock control normally open port.
 
|-
 
|-
 
|Black and purple
 
|Black and purple
|
+
|[[File:Wire_black_purple_stripe.svg|35px]]
 
|DOOR1_NC  
 
|DOOR1_NC  
 
|Lock control normally closed port.
 
|Lock control normally closed port.
 
|}
 
|}

Revision as of 17:57, 18 June 2020

Alarm Input and Output

Cable Connections
Physical Setup

Cable Connections

  • Alarm1 = Normal
  • Alarm2 = High Temp
  • No alert for mask or face detection currently.

Contact 1

Port Cable Color Cable Name Description
CON1
CON1
Black 35px RD– Negative electrode of external card reader.
Red 35px RD+ Positive electrode of external card reader.
Blue 35px CASE Tamper alarm input of the external card reader.
White File:Wire white.svg D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green File:Wire green.svg D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).
Brown File:Wire brown.svg LED Connected to external reader indicator in
Yellow File:Wire yellow.svg B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple Wire purple.png A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid

Contact 2

Port Cable Color Cable Name Description
CON2
CON2
White and red 35px ALARM1_NO Alarm 1 normally open output port
White and orange 35px ALARM1_COM Alarm 1 common output port.
White and blue 35px ALARM2_NO Alarm 2 normally open output port.
White and gray 35px ALARM2_COM Alarm 2 common output port.
White and green File:Wire white green stripe.svg GND Connected to the common GND port.
White Brown File:Wire white brown stripe.svg ALARM1 Alarm 1 input port.
White and yellow File:Wire white yellow stripe.svg GND Connected to the common GND port.
White and purple ALARM2 Alarm 2 input port.

Contact 3

Port Cable Color Cable Name Description
CON3
CON3
Black and red File:Wire black red stripe.svg RX RS-232 receiving port.
Black and orange Wire black orange stripe.svg TX RS-232 sending port.
Black and blue 35px GND Connected to the common GND port.
Black and gray File:Wire black gray stripe.svg SR1 Used for door contact detection.
Black and green File:Wire black green stripe.svg PUSH1 Door open button of door No.1
Black and brown 35px DOOR1_COM Lock control common port.
Black and yellow 35px DOOR1_NO Lock control normally open port.
Black and purple 35px DOOR1_NC Lock control normally closed port.