Cable Connections
| Port | Cable Color | Cable Name | Description |
|---|---|---|---|
| CON1 | |||
| Black | RD– | Negative electrode of external card reader. | |
| Red | RD+ | Positive electrode of external card reader. | |
| Blue | CASE | Tamper alarm input of the external card reader. | |
| White | D1 | Wiegand D1 input (connected to external card reader)/output (connected to controller). | |
| Green | D0 | Wiegand D0 input (connected to external card reader)/output (connected to controller). | |
| Brown | LED | Connected to external reader indicator in | |
| Yellow | B | RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
| |
| Purple | A | RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
|
| CON2 | |||||||